User manual

41TriStar MPPT Operator’s Manual
4.4 LED Indications
Valuable information can be provided by the three LED’s visible through the front cover. Although
there are many different LED indications, they have similar patterns to make it easier to interpret
each LED display. Consider as three groups of indications: General Transitions // Battery Status
// Faults & Alarms.
LED Display Explanation
G = green LED is lit
Y / R = yellow LED is lit, then red LED is lit
G+Y = Green and Yellow are both lit at the same time
G+Y / R = Green & Yellow both lit, then Red is lit alone
Sequencing LED patterns (faults) repeat until the fault is cleared
General Transitions
Controller start-up G / Y / R (one cycle)
Equalize request start G+Y+R / G+Y+R / G / G
Equalize cancelled G+Y+R / G+Y+R / R / R
Battery service is required* all 3 LED’s blinking until service is reset
*battery service noti cation is only enabled in custom settings
Battery Status
General state-of-charge see battery SOC indications below
Absorption state G blinking (½ second on / ½ second off)
Equalization state G fast blink (2 to 3 times per second)
Float state G slow blink (1 second on / 1 second off)
Faults & Alarms
Over-temperature Y / R sequencing
High voltage disconnect G / R sequencing
DIP switch fault R / Y / G sequencing
Self-test faults R / Y / G sequencing
Remote Temperature Sensor (RTS) G+Y / Y+R sequencing
Battery voltage sense G+Y / Y+R sequencing