User manual

37TriStar MPPT Operator’s Manual
Absorption Extension
Figure 4-3. Absorption extension charging pro le.
If battery voltage discharges below 12.50 Volts (25.00 Volts @ 24 V, 50 Volts @ 48 V) the previ-
ous night, Absorption charging will be extended on the next charge cycle as shown in gure 4-3
above. 30 minutes will be added to the normal Absorption duration.
Float Timeout
Figure 4-4. Float exit timeout charging pro le
After entering Float stage, the controller will only exit Float if the battery voltage remains below
Float voltage for 30 cumulative minutes. In gure 4-4, a system load turns on at 4:30 hrs when
the controller is in Float stage, runs for 1/2 hour, and turns off at 5:00 hrs. The load current draw
is larger than the charge current, causing battery voltage to drop below Float voltage for 30 min-
utes. After the load turns off, the controller returns to Bulk charging and then Absorption stage
once again. In this example, a load runs continuously for 30 min. However, because the Float
exit timer is cumulative, multiple momentary load events that pull the battery voltage below Float
voltage for a combined 30 minutes duration will also force an exit from Float stage.