User manual

20
Installation
Equalize Switch 7
manual OFF
automatic ON
Switch 8: Ethernet Security
The Ethernet Security switch enables or disables con guration of the TriStar MPPT settings
through the Ethernet connection. When switch eight is set to disabled, write commands to the
TriStar MPPT custom memory are not allowed. This a safety feature to prevent unintended
changes to custom settings, but it is not a replacement for proper network security.
Con guration via TCP/IP Switch 8
disabled OFF
enabled ON
NOTE:
Adjustment of network settings and custom setpoints is always enabled via the RS-232 and EIA-
485 connections. The Ethernet Security switch only enables/disables remote con guration via
TCP/IP.
!
CAUTION: Risk of Tampering
The Ethernet Security settings switch does not block write commands to devices bridged via EIA-
485.
REMARQUE :
Le réglage des paramètres de réseau et des points de consignes personnalisés est toujours
activé par les connexions RS-232 et EIA-485. Le contacteur de sécurité Ethernet n’active/
désactive que la con guration à distance par TCP/IP.
!
PRUDENCE : Risque de tentative d’altération
Le contacteur des paramètres de sécurité Ethernet ne bloque pas les commandes d’écriture sur
les dispositifs reliés par EIA-485.