User manual

18
Installation
6. Carefully align the keyhole on the TriStar MPPT with the screw head. Slide the TriStar MPPT
down over the keyhole.
7. Check for vertical plumb with a level.
8. Mark two (2) mounting hole locations in the wiring box.
9. Remove the controller and drill 3/32” (2.5 mm) holes at the drill marks.
10. Carefully align the keyhole on the TriStar MPPT with the screw head. Slide the TriStar MPPT
down over the keyhole.
11. The pre-drilled pilot holes should align with the mounting holes in the wiring box. Secure the
controller with two (2) #10 mounting screws.
12. Tighten the keyhole screw.
Step 4 - Adjust Settings Switches
Switch 1: Reserved for Future Use
Settings switch 1 should remain in the “OFF” position.
Mode Switch 1
Solar Charging OFF
future use ON
Switches 2 & 3: System Voltage
Four (4) system voltage con gurations are available as shown in the table below:
System Voltage Switch 2 Switch 3
Auto OFF OFF
12 OFF ON
24 ON OFF
48 ON ON
The “auto” setting allows the TriStar MPPT to detect the system voltage automatically on start up.
The test is only performed at start up and the detected system voltage will never change during
operation.
Generally, it is best to choose a speci c system voltage. The auto detect feature should only be
used in situations where the system voltage is unknown ahead of time or in systems where the
system voltage may change periodically.