Operation Manual
INSTALLER
Connector dimensions and pipe diameters
Gas inlet Natural 3/4”
Connections / inner Ø (mm)
Butane-Propane 3/4”
Cold Water Inlet 3/4”
Hot Water Outlet 1/2”
Flue outlet (mm)
Ø 60-100
Symbol Units Model F-11E
Power and energy consumption
Nominal output power
P
n
19,2
Mínimum output power
P
min
.
6,7
Power modulation range
P
min.
- P
n
kW 6,7-19,2
Nominal energy consumption
Q
n
22,1
Minimum energy consumption
Q
min.
8,7
Gas data
2 H Natural G20 20
2 E+ Natural G20/G25 20-25
Connection pressure
3+
Butane G30 mbar 28-30
Propane G31 37
3 B/P Butane G30 30
2 H/2 E+
Natural G20 Hi=9,45 kWh/m
3
m
3
/h
2,34
Natural G25 Hi=8,13 h/m
3
2,32
Consumo de gas
3+/(3B/P)
Butane G30 Hi=12,68 kWh/kg
kg/h
1,74
Propane G31 Hi=12,87 kWh/kg
1,72
2 H/2 E+
Natural G20 12,7
Burner pressure at Natural G25 16
nominal power
3+/(3B/P)
Butane G30
mbar
27
Propane G31 33,5
Water data
Water flow Δ 50°C l/min 2,3-5,5
Δ 25°C l/min 3,7-11
Max. operating pressure bar 13
Min. operating pressure
Max. tp. selector bar 0,12
Max. tp. selector bar 0,18
Combustion products
Flow g/s 16
Temperature °C 170
Electrical data
Electrical supply V/Hz 220-230V~50Hz
Maximum absorbed power W 35
Certification, Category and Type Modelo F-11E
EC type test certificate 99BO814
Category I
2E+
I
2H
I
3+
I
3B/P
Country of destination
BE,FR ES,GB,IE,IT,PT BE,ES,FR,GB,IE,IT,PT NL
Type C
12
Degree of electrical protection IP-44
7.- TECHNICAL CHARACTERISTICS
10