Operation Manual

8
A.2.- TECHNICAL INSTRUCTIONS FOR INSTALLATION ENGINEERS
A.2.1. TECHNICAL INFORMATION
Shape and outer dimensions
MODELS D61B - D61E G11E
Maximum 9,4 kW (135 kcal/min.) 19,2 kW (275 kcal/min.)
Minimum 5,6 kW (81 kcal/min.) 10 kW (145 kcal/min.)
BA C D E F G H I J L M
634310 230 276 110 660 115 235 464 50 456 45G11E
573266 190 236 90 589 97 120 350 50 344 45
D61B/D61E
SELECTOR SETTING
DESOLCNEPOSLEDOM
Water ow T Water ow T
D61B-D61E
5,4 litres/min. 25ºC 2,7 litres/min. 50ºC
G11E 11 litres/min. 25ºC 5,5, litres/min. 50ºC
SPECIFICATIONS
Available caloric power
Output in terms of a p.c.i. over 85%
HOT WATER DELIVERY
The gures quoted are for the appliance at normal operating pressure at minimum
and maximum selector settings.
NOTE: Temperatures are in degrees rise above ambient.
OPERATING PRESSURE
Minimum 1bar Maximum 10 bar
Water inlet pressure with the appliance working at normal pressure.
Ø E
G
Lower of base
H
J
CW
WW
WW
CW
GAS
GAS
M
C
D
A
Temperature selector
Control knob
Ignition window
L
I
F
B