Operation Manual

3.
CH
temperature
control
knob
This has 3 functions:
1.
Set the CH target temperature between 30 deg C and 80 deg C
2.
Select heating mode ON
or
OFF
3.
The service mode is set by turning the knob fully
clockwise-
this
is only for use
by
engineers
Service
Mode
MAX.
4.
DHW
Temperature
control
knob
This has 3 functions:
.----Heating
OFF
,--------+---Heating
ON
MIN
1.
Set the DHW target temperature between 35 deg C and 60
deg C
2. Select comfort/economy mode - change between these
modes by turning the knob fully clockwise and then back
within 3 seconds.
3. The DHW supply can be switched off by turning the knob
fully anti-clockwise.
Comfort/ECO
Mode
Selection
5.
CH
Pressure
test
button
--...-..-.~...-..
=--===:;;=
-
·==-
···~--
..
~
----t--Hot
Water OFF
'------------.--
Hot Water ON
MIN
COMFORT
'
This is used to see what pressure is held
in
the CH circuit - it should
read between1.0 -1.4 bar. In order to see the pressure on the LCD display,
push the button. The value will be displayed for approximately 10 seconds.
6.
Reset push button/ burner LED
This is used to reset the boiler after
any
fault codes are displayed on the LCD panel.
In addition the colour
of
the LED indicates the following:
Red LED - the boiler is in fault mode and a code should be visible on the LCD panel
Blue
LED-
the boiler is operating normally and the burner is ignited
6