6.9 FAULT CODE/LOCK OUT
If the boiler develops a fault the reset button will show red and a fault code will show
on
the LCD panel. See Fault codes
in
chapter 9 for further details.
To reset the boiler after a fault, press the reset button and it should change from red
to either:
Clear if the boiler is unlit or
Blue if the boiler is lit.
6.10 FINAL CHECKS
Re-light and test for gas soundness
Set the C.H. and D.H.W. temperature selectors to the required settings.
Ensure that the timer/thermostat/programmer are set to the required settings.
6.11 USER INSTRUCTIONS
Upon Commissioning
of
the boiler the engineer should:
Give the 'users Instructions' to the owner and emphasise their responsibilities
under the "Gas Safety (Installation and Use) Regulations 1998"
Explain and demonstrate the lighting and shut down procedures.
Advise the owner
on
the efficient use
of
the system, including the use and
adjustment of all system controls for both D.H.W. ana
C.
H.
Advise the user
of
the precautions necessary to prevent damage to the system,
and
tq
the home,
in
the event
of
the system remaining inoperative during frost
cond1t1ons.
Explain the function
of
the boiler safety devices, fault codes and how to reset
them. Emphasise that if fault codes and lock outs persist, the boiler should be
turned off and a Gas Safe Engineer consulted.
Stress the importance
of
an
annual service by a competent Gas Safe Registered
Engineer.