Owner`s manual

Manual Part No: 930093-01 MD Electric Convection Range - 15 –
Manual Rev No: 1
INSTALLATION
Important
This appliance MUST be installed by a competent person in accordance with these and any other relevant
regulations.
The installation wiring
MUST comply with the latest I.E.E. Regulations.
WARNING: THIS APPLIANCE MUST BE ELECTRICALLY EARTHED
Before Installation
Before commencing installation, remove all packaging materials from the appliance. It is suggested that
any protective film adhering to the stainless steel panels should be left on until installation is completed.
BUT THIS MUST BE REMOVED BEFORE COMMISSIONING OR OPERATING THE APPLIANCE.
Check the appliance Data Plate (located on the rear of the flue upstand/splashback), to ensure that the
appliance is suitable for the electricity supply available.
Ensure that the floor upon which the appliance is to stand is level and capable of adequately supporting
the weight of the appliance.
TO COMPENSATE FOR SOME UNEVENNESS OF THE FLOOR, THE
APPLIANCE FEET ARE ADJUSTABLE.
THE FLOOR MUST BE FIREPROOF. If it is not, or if any adjacent wall or surface is made of a combustible
material, then the installer must ensure that the requirements of the
LOCAL FIRE REGULATIONS are
observed.
Positioning
Place the appliance in position allowing a minimum gap of 150 mm (6”) at the rear and at least 150mm
(6”)* between the sides of the appliance and any adjacent wall. If the appliance is being suited then
please refer to the separate instructions. The minimum distance between the hotplate/work surface and
any overshelf or ceiling constructed of a combustible material must be 1525 mm (60”).
Ensure that the appliance is level in two places - front to rear and side to side. To check the level it is
recommended that a spirit level be placed on a shelf in the oven (
NOT on top of the hotplate) or the
work surface. Level can be achieved by adjusting any or all of the screw in feet in each corner of the
base. Turn anti-clockwise to lower and clockwise to raise the corner. It is recommended that the
appliance be sited below a ventilating hood, one preferably connected to an extractor system
incorporating a grease filter.