Owner`s manual
Manual Part No: 930004-01 MD Gas Range - 34 –
Manual Rev No: 1
Service and Maintenance (cont.)
10) To Convert NG Appliances to LP Gas
. (Open Top)
Remove the control knobs and control panel, which is secured by two fixing screws.
Remove the pan supports.
Remove the hotplate burner injectors as described in Section 5 and fit replacement 1.04mm LP
injectors (924724-07) and re-fit burner caps etc.
Working from the front of the appliance screw in fully both the thermostat and Gas Tap/FFD by-
pass screws.
From inside the oven remove the oven injector as described in Section 3 and fit replacement LP
injector.
900 Range – 1.32mm (924024-09)
600 Range – 1.18mm (924024-06)
Remove the gas governor from the inlet supply pipe.
Finally fit replacement Data Plate and re-test the appliance.
11) To Convert LP Appliances to NG Gas
. (Open Top)
Proceed as described in Section 10, but substituting NG replacement parts.
Hotplate Injector 1.70mm (924724-06)
Oven Injector 900 2.44mm (924024-08)
Oven injector 600 1.99mm (924024-10)
Governor (X03041)
Fit replacement gas governor to the inlet supply pipe.
Turn the thermostat by-pass screw anti-clockwise and light the oven burner. Ensure that when
the burner cuts-down to by-pass rate the flame envelops the thermocouple tip sufficiently to
keep the magnet valve open.
If the flame extinguishes turn the by-pass screw anti-clockwise until the flame is established.
Repeat the above procedure for the hotplate by-pass rates.
Finally fit replacement Data Plate and re-test the appliance.