Instruction manual

- 6 -
STANDARD INSTALLATION PROCEDURES
INCLUDES MODEL: WM20G
1. Choose an appropriate location on an outside wall to mount the WM20G.
NOTE: Be sure that the wall is sturdy enough to support the combined
weight of the bracket and housing.
2. Place the base against the wall, mark the location of the four mounting
holes, remove the bracket and drill the mounting holes. Pull all wiring
through the wall at this
time (Figure 1).
3. Run wiring into and through the WM20G bracket. Make sure you also
have enough to run into the housing for connections.
NOTE: For applications where the wiring cannot be pulled through the wall,
a starter hole is provided on the side of the bracket near the base. Use this
to drill a larger hole to pass conduit into and through the bracket (Figure 2).
Figure 1
Starter
Hole
Figure 2
Figure 3
Figure 4
Figure 5
4. Mount the WM20G to the wall (hardware not included). (Figure 3)
5. Make all wiring connections to the housing, following instructions provided
with the housing (Figure 4).
6. Screw the housing coupling onto the WM20G 1½" pipe thread (Figure 5).
Make sure all attachments are secure.
NOTE: Use Teon™ tape or
silicone to seal the threads