User`s manual

CHAPTER 3.0 Wiring and Installation 3-57
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
3.13.3 C Size Power Stage
- Fixed connector: 5 pins, male connector
- Mating connector, 5 pins, female, crimped supplied with the drive. (Molex 42816-0512)
- C size wiring: cable 8 AWG (8.4 mm
2
).
Pos. Name Function
J6.1 W1
Phase "L3", ", three-phase voltage input 230/460Vac ±10%
J6.2 V1
Phase "L2", ", three-phase voltage input 230/460Vac ±10%
J6.3 U1
Phase "L1", three-phase voltage input 230/460Vac ±10%
J6.4 +ATP DC Bus (+) (Regeneration Resistor connection)
J6.5 RR Regeneration Resistor
- Fixed connector: 4 pins, male connector
- Mating connector, 4 pins, female, crimped supplied with the drive. (Molex 42816-0412)
- C size wiring: cable 8 AWG (8.4 mm
2
).
Pos. Name Function
J7.1 U2 Motor Phase U
J7.2 V2 Motor Phase V
J7.3 W2 Motor Phase W
J7.4 PE Motor Protective Earth
- Fixed connector: 2 pins, male connector
- Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000)
- C & D size wiring: cable 14 AWG (2.1 mm
2
).
- Stripping Length 8mm
Pos. Name Function
J8.1 24V +24V Logic Backup Supply
J8.2 0V Logic Supply Return
- Fixed connector: 2 pins, male connector
- Mating connector, 2 pins, female, crimped supplied with the drive. (Molex 42816-0212)
- C size wiring: cable 8 AWG (8.4 mm
2
).
Pos. Name Function
J9.2 +AT DC Bus (+)
J9.1 -AT DC Bus (-)
- PE Stud wiring: cable 6 AWG (13mm
2
)
Pos. Name Function
PE PE Protective Earth Stud on Chassis