User`s manual

CHAPTER 3.0 Wiring and Installation 3-56
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
3.13.2 A & B Size Power Stage
- Fixed connector: 12 pins, male connector
- Mating connector, 12 pins, female, supplied with the drive. Phoenix Contact (Part # 1767106)
- A size wiring: cable 14AWG (2.1 mm
2
). Wire stripping: 7 mm
- B size wiring: cable 12AWG (3.3 mm
2
). Wire stripping: 7 mm
- Tightening torque: 0.5Nm.
Pos. Name Function
J6.1 -AT DC Bus (-)
J6.2 +AT DC Bus (+)
J6.3 RR Regeneration Resistance
J6.4 U1
Phase “L1”, three-phase voltage input 230/460Vac ±10%
J6.5 V1
Phase “L2”, “, three-phase voltage input 230/460Vac ±10%
J6.6 W1
Phase “L3”, “, three-phase voltage input 230/460Vac ±10%
J6.7 PE Motor Protective Earth
J6.8 W2 Motor Phase W
J6.9 V2 Motor Phase V
J6.10 U2 Motor Phase U
J6.11 24V +24V Logic Backup Supply
J6.12 0V Logic Supply Return
- Fixed connector: 2 pins, male connector
- Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000)
- C & D size wiring: cable 14 AWG (2.1 mm
2
).
- Stripping Length 8mm
Pos. Name Function
J8.1 24V +24V Logic Backup Supply
J8.2 0V Logic Supply Return
- PE Stud wiring: cable 6 AWG (13mm
2
)
Pos. Name Function
PE PE Protective Earth Stud on Chassis