User`s manual
CHAPTER 3.0 Wiring and Installation 3-50
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
3.11.1 General Purpose Description of the Digital Inputs
The DS2110 provides 8 digital inputs on connector J2A.
- Fixed connector: 9 pins, male connector
- Mating connector, 9 pins spring cage, female, supplied with the drive. Phoenix Contact (Part # FK-MC 0.5/9-
ST-2.5)
- Wiring: cable. 28-20AWG (0.14-0.5mm
2
)
- Wire stripping: 8 mm
Pos. Name Function
J2A.1 I1 Digital Input # 1 Drive Enable
J2A.2 I2 Digital Input # 2 User Configurable
J2A.3 I3 Digital Input # 3 User Configurable
J2A.4 I4 Digital Input # 4 User Configurable
J2A.5 I5 Digital Input # 5 User Configurable
J2A.6 I6 Digital Input # 6 User Configurable
J2A.7 I7 Digital Input # 7 User Configurable
J2A.8 I8 Digital Input # 8 User Configurable
J2A.9 RET Digital Input Ground
Table 3. -24 J2A, DS2110 Digital Input connector
The following electrical description applies to all the digital inputs of the DS2110.
+5V
4K7Digital Input I1-I8
SIGNAL
Optocoupler
RET
3V3
Figure 3.43 DS2110 Generic Digital Inputs
Note that:-
Input Impedance > 5k ohm.
Voltage Range is 12V to 32V from Digital-Input to the I_COMMON line. Inputs are protected for input voltages
from –40V to +40V
Input voltages whose magnitude is less than 12V with respect to the I_COMMON line will not be
guaranteed to be recognised as an active signal input.
Input voltages whose magnitude is more than 5V with respect to the I_COMMON line will not be
guaranteed to be recognised as an inactive signal input
All digital inputs are optically isolated for noise immunity purposes. All DS2110 digital inputs are isolated
from high voltage circuitry internally
Current flowing in the digital input implies the 'safer' of the corresponding active/inactive functions. For
example, when current flows in the clockwise limit switch input, then the limit is NOT active.