User`s manual

CHAPTER 3.0 Wiring and Installation 3-47
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
3.10.5 Motor Encoder Connection
The DS2110 encoder input supports a variety of encoders. These include Analogue, SSI, Hiperface and Endat.
The connections to the drive for each of these encoder types are given in Table 3-28.
Encoder
Connector
Figure 3.40 Motor Encoder Connector Location
- Fixed connector: 15 pin, female Sub-D connector
- Mating connector, 15pin male Sub-D
- Wiring: cable. 28-18AWG (0.14-0.82mm
2
)
Encoder Type
Pos Analogue SSI Hiperface Endat
J4.1 Shield Shield Shield Shield
J4.2 - Sine - - Sine - Channel B
J4.3 - Cosine - - Cosine - Channel A
J4.4 Gnd Supply Gnd Supply Gnd Supply Gnd Supply
J4.5 - - Clock - - Clock
J4.6 - Channel Z (Zero) - Data RS485 - - Data
J4.7 - - - -
J4.8 NTC/PTC NTC/PTC NTC/PTC NTC/PTC
J4.9 + Sine - + Sine + Channel B
J4.10 + Cosine - + Cosine + Channel A
J4.11 +5 V .. +12V Supply
(150 mA max.)
+5 V .. +12V Supply
(150 mA max.)
+5 V .. +12V Supply
(150 mA max.)
+5 V .. +12V Supply
(150 mA max.)
J4.12 - Fault + Clock - + Clock
J4.13 + Channel Z (Zero) + Data RS485 + + Data
J4.14 Gnd Supply Gnd Supply Gnd Supply Gnd Supply
J4.15 NTC/PTC NTC/PTC NTC/PTC NTC/PTC
Table 3. -23 Encoder Cable Input Connections
For CE compliance, shield should be attached on both sides of encoder cable.
Required for
CE-Compliance
NOTE:- Avoid running the encoder cable near other high power
wiring, especially the motor power cable, if possible.
NOTE:- Cable Length should not exceed 30m (100 feet).