User`s manual

CHAPTER 3.0 Wiring and Installation 3-38
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
3.10.2.2 Size A & B
PE
GND (J6.7)
M o t o r
U2 (J6.10)
V2 (J6.9)
g r o u n d i n g o f s h i e l d
v i a c o n n e c t o r c l a m p
W2 (J6.8)
V
W
U
grounding of shield
via connector clamp
(or RF connection to
ground screw in
case of terminal board)
J6
DS2110 A, B
Figure 3.31 DS2110 A & B Motor Power Connection
- Fixed connector: 10 pins, male connector
- Mating connector, 10 pins, female, supplied with the drive. Phoenix Contact (Part # PC4 HV/10-ST-7.62)
- A size wiring: cable 14AWG (2.1 mm
2
). Wire stripping: 7 mm
- B size wiring: cable 12AWG (3.3 mm
2
). Wire stripping: 7 mm
- Tightening torque: 0.5Nm.
-
Pos. Name Function
J6.7 GND Motor Protective Earth
J6.8 W2 Motor Phase W
J6.9 V2 Motor Phase V
J6.10 U2 Motor Phase U
Table 3. -16 J6, Motor connector, A & B Size