User`s manual
CHAPTER 3.0 Wiring and Installation 3-37
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
3.10.2.1 Size µA
PE
PE (J6.7)
M o t o r
U (J6.10)
V (J6.9)
g r o u n d i n g o f s h i e l d
v i a c o n n e c t o r c l a m p
W (J6.8)
V
W
U
grounding of shield
via connector clamp
(or RF connection to
ground screw in
case of terminal board)
J6
DS2110
μ
A
Figure 3.30 DS2110 µA Motor Power Connection
- Fixed connector: 12 pins, male connector
- Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-
7.62)
- µA size wiring: cable 14 AWG (2.1 mm
2
). Wire stripping: 7 mm.
- Tightening torque: 0.5Nm.
Pos. Name Function
J6.7 PE Motor Protective Earth
J6.8 W Motor Phase W
J6.9 V Motor Phase V
J6.10 U Motor Phase U
Table 3. -15 J6, Motor connector, µA Size