User`s manual
CHAPTER 3.0 Wiring and Installation  3-37
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
3.10.2.1 Size µA 
PE 
PE (J6.7) 
M o t o r 
U (J6.10) 
V (J6.9) 
g r o u n d i n g  o f  s h i e l d 
v i a  c o n n e c t o r  c l a m p 
W (J6.8) 
V 
W 
U 
grounding of shield 
via connector clamp 
(or RF connection to 
ground screw in 
case of terminal board) 
J6 
DS2110 
μ
A 
Figure 3.30 DS2110 µA Motor Power Connection 
-  Fixed connector: 12 pins, male connector 
-  Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-
7.62) 
-  µA size wiring: cable 14 AWG (2.1 mm
2
). Wire stripping: 7 mm. 
-  Tightening torque: 0.5Nm. 
Pos. Name  Function 
J6.7  PE  Motor Protective Earth 
J6.8 W  Motor Phase W 
J6.9 V  Motor Phase V 
J6.10 U  Motor Phase U 
Table 3. -15 J6, Motor connector, µA Size 