CHAPTER 3.0 Wiring and Installation 3-34
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
3.9.3 C Size Regeneration Resistor connection
Tie screen to
panel on
which resistor
is mounted.
Tie Screen to
chassis via EMC
bracket. See
Section 2
Installation
J6.4 J6.5
+ATP RR
Connector J6
DS2110 C
Recovery
Resistor
Figure 3.27 DS2110 Size C External Regeneration Connections
J6
- Fixed connector: 5 pins, male connector
- Mating connector, 5 pins, female, crimped supplied with the drive. (Molex 42816-0512)
- C size wiring: cable 8 AWG (8.4 mm
2
).
Pos. Name Function
J6.4 +ATP DC Bus (+)
J6.5 RR Regeneration Resistor
Table 3. -12 J6, Regeneration Resistor connector, C Size
3.9.4 D Size Regeneration Resistor connection
Tie screen to
panel on
which resistor
is mounted.
Tie Screen to
chassis via EMC
bracket. See
Section 2
Installation
J9.2 J9.1
+ATP RR
Connector J9
DS2110 D
Recovery
Resistor
Figure 3.28 DS2110 Size D External Regeneration Connections
J9
- Fixed connector: 2 pole, screw terminal
- D size wiring: cable 6 AWG (13 mm
2
) for 50/140
- D size wiring: cable 4 AWG ( 21mm
2
) for 60/180
- Stripping Length 16mm
- Tightening Torque: 2-2.3Nm
Pos. Name Function
J9.1 RR Regeneration Resistor
J9.2 +ATP DC Bus (+)
Table 3. -13 J9, Regeneration Resistor connector, D Size