User`s manual
CHAPTER 3.0 Wiring and Installation  3-29
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
3.8  24V Backup Connection 
The DS2110 is equipped with a 24V logic supply backup. This backup supply provides logic power to the drive 
when AC mains power is removed. 
For the µA size, this backup is mandatory for drive operation. 
3.8.1  Size µA 24V Input Connection 
 11 12
 11 12
 Connector J6
μ
DS
24V Auxiliary
Supply
+24V
GND (0V)
 Connector J6
μ
DS
Fairrite Clamp Core
p/n # 00443164151
(4-Turns of Supply
cable)
Fuse
Figure 3.22 Size µA 24V DC Input Connection 
-  Fixed connector: 12 pins, male connector 
-  Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-
7.62) 
-  A size wiring: cable 14 AWG (2.1 mm
2
). 
-  Stripping Length 7mm 
-  Tightening torque: 0.5Nm. 
Pos. Name  Function 
J6.11  24V  +24V Logic Backup Supply 
J6.12  0V  Logic Supply Return (Tied Internally to PE ) 
Table 3. -7 J6 24V Logic Power connector, µA Size 