User`s manual
CHAPTER 3.0 Wiring and Installation  3-24
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
3.7.1  AC Mains Power Source Connection 
3.7.1.1 Size µA 
EMC Filter, 
Fuses etc. 
See 
Section 2 
Installation 
 4  5  6  
 L1  L2    L3  
Connector J6
μ
A 
 4  5  6  
 L1   L2    L3   
Connector J6 
μ
A 
PE 
Stud 
PE 
Stud 
a.c. Mains
L1 
L2 
L3 
Protective 
Earth 
Figure 3.17 µA AC Mains Input Connection 
-  Fixed connector: 12 pins, male connector 
-  Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-
7.62) 
-  A size wiring: cable 14 AWG (2.1 mm
2
). Wire stripping: 7 mm. 
-  PE Stud wiring: cable 6 AWG (13mm
2
) 
-  Tightening torque: 0.5Nm. 
Pos. Name  Function 
J6.4  L1 
Phase "L1", three-phase voltage input 230/460Vac ±10% 
J6.5 L2 
Phase "L2", ", three-phase voltage input 230/460Vac ±10% 
J6.6 L3 
Phase "L3", ", three-phase voltage input 230/460Vac ±10% 
PE  PE  Protective Earth Stud on Chassis 
Table 3. -3 J6 AC Mains Power connector, µA Size 