User`s manual
APPENDIX F – DEVICENET
TM
 MEZZANINE CARD  F-11 
CDS7324 (FORMERLY LSF-0819)
Rev. A     INSTALLATION & USER’S MANUAL 
jogging 
JOG_SPEED  65273  f32  0  - FLT_MAX  FLT_MAX  0x74  0x4A  Jog Speed 
JOG_ACC  65274  f32  0  0  FLT_MAX  0x74  0x4B  Acceleration time during Jog 
JOG_DEC  65275  f32  0  0  FLT_MAX  0x74  0x4C  Decceleration time during Jog 
ACT_POS  65300  f32  0  - FLT_MAX  FLT_MAX  0x75  0x01  Actual Position 
ACT_VEL  65301  f32  0  - FLT_MAX  FLT_MAX  0x75  0x02  Actual Rod Speed 
ACT_FORCE 65302 f32 0 - FLT_MAX FLT_MAX 0x75 0x03 Actual Force 
FAULT_STATUS 65303 u32 0 0 ULONG_MAX  0x75  0x04  Current Fault status 
GUI_DRIVE_ENABLE  65304  u16  0  0  1  0x75  0x05  GUI Command: Drive Enable 
GUI_JOG_EXTEND_CMND  65305  u16  0  0  1  0x75  0x06  GUI Command: Jog Extend 
GUI_JOG_RETRACT_CMND  65306  u16  0  0  1  0x75  0x07  GUI Command: Jog Retract 
GUI_PROFILE_SELECT  65307  u16  0  0  7  0x75  0x08  GUI Command: Profile Select 
GUI_START_CMND  65308  u16  0  0  1  0x75  0x09  GUI Command: Start Motion 
GUI_STOP_CMND  65309  u16  0  0  1  0x75  0x0A  GUI Command: Stop Motion 
GUI_FAULT_RESET_CMND  65310  u16  0  0  1  0x75  0x0B  GUI Command: Stop Motion 
ANALOG_INPUT1_OFFSET  65311  s16  0  -32767  32767  0x75  0x0C  Analog Input 1 offset 
ANALOG_INPUT1_FULLSCALE  65312  f32  32768  -65535  65535  0x75  0x0D  Analog Input 1 Fullscale 
ACTUATOR_CENTER_POSITION 65313  f32  0 - FLT_MAX  FLT_MAX  0x75 0x0E 
Actuator Center Position - For 
lubrication 
GUI_CENTER_ACTUATOR 65314 u16 0  0  1 0x75 0x0F  GUI Command: Center Actuator 
ANALOG_OUTPUT1_OFFSET 65315 f32 32768 -65535  65535  0x75  0x10  Analog output 1 offset 
ANALOG_ 
OUTPUT1_FULLSCALE  65316  f32  32768  -65535  65535  0x75  0x11  Analog Input 1 Fullscale 
FIELDBUS_ 
POS_SCALE_FACTOR 65520 f32 1 0 1 0x75 0x15 
Scale Factor for scaling Move 1 
Position when using field bus: 
Target Position = Move 1 
Position * Scale Factor 
FIELDBUS_ 
VEL_SCALE_FACTOR 
65521 f32  1  0  1  0x75 0x16 
Scale Factor for scaling Move 1 
Velocity when using field bus: 
Target Velocity = Move 1 
Velocity * Scale Factor 
FIELDBUS_ 
FORCE_SCALE_FACTOR 
65522 f32  1  0  1  0x75 0x17 
Scale Factor for scaling Move 1 
Max. Peak Force when using 
field bus: Max Force = Max Peak 
Force * Scale Factor 
FIELDBUS_  65523  f32  1  0  1  0x75  0x18  Scale Factor for scaling Move 1 