User`s manual

APPENDIX F – DEVICENET
TM
MEZZANINE CARD F-9
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
MOVE_TYPE_1 65201 u16 0 0 2 0x74 0x02
Select Move Type: 0=Absolute,
1=Relative, 2=Compound
MOVE_TARGET_1 65202 f32 0 - FLT_MAX FLT_MAX 0x74 0x03
Select Move Target Position for
Move 1
MOVE_SPEED_1 65203 f32 0 - FLT_MAX FLT_MAX 0x74 0x04 Select Move Speed for Move 1
MOVE_ACC_1 65204 f32 0 0 FLT_MAX 0x74 0x05
Select Move Acceleration for
Move 1
MOVE_DEC_1 65205 f32 0 0 FLT_MAX 0x74 0x06
Select Move Deceleration for
Move 1
ANALOG_INPUT_SELECTOR 65206 u16 1 0 1 0x74 0x07
Select analog input (0=Analog
Input 1, 1=Analog Input 2)
COMMAND_DIRECTION 65207 u16 0 0 1 0x74 0x08
Select Analog Command
Direction (0=RetractToExtend for
Increasing V or mA,
1=ExtendToRetract for
Increasing V or mA)
NEUTRAL_
POSITION_SELECTOR 65208 u16 0 0 6 0x74 0x09
Select Neutral Position on mA
Command Loss (0=Act.Pos,
1=Move 2, 2=Move3 ... 6=Move7
Position)
ANALOG_
COMMAND_DEADBAND
65209 f32 0 0 FLT_MAX 0x74 0x0A
Set analog command deadband -
Drive will ignore command
change smaller than this setpoint
MOVE_TYPE_2 65211 u16 0 0 2 0x74 0x0C
Select Move Type: 0=Absolute,
1=Relative, 2=Compound
MOVE_TARGET_2 65212 f32 0 - FLT_MAX FLT_MAX 0x74 0x0D
Select Move Target Position for
Move 2
MOVE_SPEED_2 65213 f32 0 - FLT_MAX FLT_MAX 0x74 0x0E Select Move Speed for Move 2
MOVE_ACC_2 65214 f32 0 0 FLT_MAX 0x74 0x0F
Select Move Acceleration for
Move 2
MOVE_DEC_2 65215 f32 0 0 FLT_MAX 0x74 0x10
Select Move Deceleration for
Move 2
MOVE_TYPE_3 65221 u16 0 0 2 0x74 0x16
Select Move Type: 0=Absolute,
1=Relative, 2=Compound
MOVE_TARGET_3 65222 f32 0 - FLT_MAX FLT_MAX 0x74 0x17
Select Move Target Position for
Move 3
MOVE_SPEED_3 65223 f32 0 - FLT_MAX FLT_MAX 0x74 0x18 Select Move Speed for Move 3
MOVE_ACC_3 65224 f32 0 0 FLT_MAX 0x74 0x19
Select Move Acceleration for
Move 3
MOVE_DEC_3 65225 f32 0 0 FLT_MAX 0x74 0x1A Select Move Deceleration for