User`s manual
APPENDIX F – DEVICENET
TM
 MEZZANINE CARD  F-3 
CDS7324 (FORMERLY LSF-0819)   
Rev. A     INSTALLATION & USER’S MANUAL 
F.7 Units 
The drive parameters are in engineering units. Based on the value of the UNITS parameter, the values 
are either interpreted as METRIC (0) or ENGLISH (1). Hence parameters written over the fieldbus must 
be written in the correct units. 
F.8 PARAM_UPDATE_in 
Parameters that pertain to the actuator performance, geometry and motion will not take effect on the 
drive unless the PARAM_UPDATE_in parameter is set to 1 and the drive is disabled and the drive is 
not faulted. This is a safety precaution to avoid unexpected actuator movement. The 
PARAM_UPDATE_in parameter will auto-reset to 0 after the drive has recalculated parameters. 
F.9 Implicit I/O 
The following parameters are available for Implicit I/O exchange. The parameters take up a total of 16 
bytes for input and 16 bytes for output of Polled I/O. See the Parameter List table on the following 
pages for further detail on the parameters. 
Input to the Drive = Output from Scanner/PLC  Output from the Drive = Input to Scanner/PLC 
CMND_WORD STATUS_WORD 
FIELDBUS_POS_SCALE_FACTOR ACT_POS 
FIELDBUS_VEL_SCALE_FACTOR ACT_VEL 
FIELDBUS_FORCE_SCALE_FACTOR ACT_FORCE 