User`s manual

APPENDIX E – ANALOG I/O MEZZANINE CARD E-5
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
1
6
9
5
E.5.2 Assigning SSI
In the following parameter, a number may be entered that will output any internal variable through the SSI
interface:
mezssivarfld 1894 UNSIGN16 SSI variables field number
For example, the SSI parameter, mezssivarfld, for the Maxforce Application is entered as 64078. This represents
the SSIPOS model parameter.
SSIPOS 64078 SIGN32 Position for SSI feedback in counts = Pos minus
MaxForce Home Offset
Refer to specific application manual for more details on this parameter association.
E.6 Simulated Encoder/Resolver
E.6.1 Interface
The Simulated Encoder is a 9 pin D-sub male connector (J5B). The pinouts are illustrated in Figure E9.
Figure E9 J5B Pin Configuration
E.6.2
Parameters
The database parameters related to the Simulated Encoder Signal Generation Feature are shown in Figure 10.
To enable the feature, parameter 2031 must be set to 1, the other configuration parameter default values should
be sufficient.
Pin Function
1 Simulated Sine (+)
2 Simulated Cosine (+)
3 Data Out (+)
4 Chassis GND
5 Clock In (+)
6 Simulated Sine (-)
7 Simulated Cosine (-)
8 Data Out (-)
9 Clock In (-)
Simulated
Encoder /SSI
Output Pin
Configuration