User`s manual

APPENDIX B – GUI B-60
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.70.3 Channel Panels
Status: Sets the channel to visible, hidden, or off.
Source: Represents which parameter is logged.
Scaling: Represents the vertical scaling for this channel.
Offset: Represents the vertical offset for this channel.
B.2.16.70.4 Cursor Panel
Allows 2 cursors to measure on the vertical axis, horizontal axis or a combination of both.
Also automatically displays the difference between the cursors in time and frequency.
B.2.16.70.5 Trigger Panel
Status: Displays the current status of the oscilloscope. This can be one of the following:
o Stopped: The oscilloscope is currently not logging any data.
o Waiting: The oscilloscope is currently waiting for the trigger to fire.
o Sampling: The oscilloscope is currently sampling.
Source: Represents the parameter which is used for triggering.
Level: The value at which the trigger will fire.
Delay: Allows setting of trigger delay or pre-trigger.
Coupling: Coupling can be dc, ac, or bitmap masking.
Slope: Determines whether to trigger on a rising or falling slope.
Mode: Can be set by the user. This can be one of the following:
o Continuous: The oscilloscope will sample from firing of trigger continuously.
o Single: The oscilloscope will sample from firing of trigger for number of samples.
o Roll: The oscilloscope will sample continuously (ignoring trigger settings).
o Stop: The oscilloscope will stop sampling.