User`s manual

APPENDIX B – GUI B-52
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.59 Drive Status Byte 4
DRIVE STATUS BYTE 4 :
Phase A Current Offset Indicates if the DSP phase A current offset is greater than a programmable limit.
Phase B Current Offset Indicates if the DSP phase B current offset is greater than a programmable limit.
Motor Thermal Warning indicates that the motor winding temperature is within 10% of the motor max
temperature.
Bridge Thermal Warning Indicates that the power transistor heatsink temperature is within 10% of the
bridge maximum temperature.
Regen Warning Indicates that the power dissipated in the regen resistor(s) is within 10% of the continuous
capability of the resistor(s).
Limit Switch hit Warning Indicates that either clockwise or counter-clockwise limit switch has become
active.
B.2.16.60 Drive Status Byte 5
DRIVE STATUS BYTE 5 :
Model Initialization fault Indicates the model has failed either the initialization function or parameter access.
Model Run fault Indicates the model has returned an error while running.
Model Programming fault Indicates a programming error in the model.