User`s manual
APPENDIX B – GUI B-52
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.59 Drive Status Byte 4
DRIVE STATUS BYTE 4 :
• Phase A Current Offset → Indicates if the DSP phase A current offset is greater than a programmable limit.
• Phase B Current Offset → Indicates if the DSP phase B current offset is greater than a programmable limit.
• Motor Thermal Warning → indicates that the motor winding temperature is within 10% of the motor max
temperature.
• Bridge Thermal Warning → Indicates that the power transistor heatsink temperature is within 10% of the
bridge maximum temperature.
• Regen Warning → Indicates that the power dissipated in the regen resistor(s) is within 10% of the continuous
capability of the resistor(s).
• Limit Switch hit Warning → Indicates that either clockwise or counter-clockwise limit switch has become
active.
B.2.16.60 Drive Status Byte 5
DRIVE STATUS BYTE 5 :
• Model Initialization fault → Indicates the model has failed either the initialization function or parameter access.
• Model Run fault → Indicates the model has returned an error while running.
• Model Programming fault → Indicates a programming error in the model.