User`s manual
APPENDIX B – GUI B-51
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.57 Drive Status Byte 2
DRIVE STATUS BYTE 2 :
• Enable Attempted → Indicates that an attempt was made to enable the drive when the conditions for enabling
were not valid (e.g. hardware enable false).
• Encoder Supply → Indicates an encoder supply fault.
• Motor Thermal Foldback Warning → Indicates that the temperature is within 10% of the start temperature for
motor thermal foldback
• Bridge Thermal Foldback Warning → Indicates that the temperature is within 10% of the start temperature for
bridge thermal foldback
B.2.16.58 Drive Status Byte 3
DRIVE STATUS BYTE 3 :
• Drive OK → Shows the drive resources state. Drive resources are those that would be exclusive to a single
axis in a multi-axis drive.
• Position Error in Limits → Indicates that the actual position has attained the target position within a
programmable range. Valid in position mode only.
• Thermal Limiting → Indicates whether the thermal limiting is active.