User`s manual

APPENDIX B – GUI B-51
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.57 Drive Status Byte 2
DRIVE STATUS BYTE 2 :
Enable Attempted Indicates that an attempt was made to enable the drive when the conditions for enabling
were not valid (e.g. hardware enable false).
Encoder Supply Indicates an encoder supply fault.
Motor Thermal Foldback Warning Indicates that the temperature is within 10% of the start temperature for
motor thermal foldback
Bridge Thermal Foldback Warning Indicates that the temperature is within 10% of the start temperature for
bridge thermal foldback
B.2.16.58 Drive Status Byte 3
DRIVE STATUS BYTE 3 :
Drive OK Shows the drive resources state. Drive resources are those that would be exclusive to a single
axis in a multi-axis drive.
Position Error in Limits Indicates that the actual position has attained the target position within a
programmable range. Valid in position mode only.
Thermal Limiting Indicates whether the thermal limiting is active.