User`s manual
APPENDIX B – GUI  B-50 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
B.2.16.56  Drive Status Byte 1 
DRIVE STATUS BYTE 1 : 
•  Loss of Encoder Fault → Indicates that the encoder is disconnected, but has been selected as a feedback 
source. 
• Short Circuit Top → Indicates a short circuit fault 
•  Loss of Resolver Fault → Indicates that the resolver is disconnected, but has been selected as a feedback 
source. 
•  Bridge Over Temperature → Indicates that the bridge temperature has exceeded the upper limit. 
•  Motor Over Temperature → Indicates that the motor temperature has exceeded the upper limit. 
• Short Circuit Bottom → Indicates a short circuit fault 
• Velocity Rampdown → Indicates a timeout fault during a velocity rampdown (quickstop). 
• Manual Mode → Indicates whether manual mode is enabled. This is a warning only. 