User`s manual
APPENDIX B – GUI B-50
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.56 Drive Status Byte 1
DRIVE STATUS BYTE 1 :
• Loss of Encoder Fault → Indicates that the encoder is disconnected, but has been selected as a feedback
source.
• Short Circuit Top → Indicates a short circuit fault
• Loss of Resolver Fault → Indicates that the resolver is disconnected, but has been selected as a feedback
source.
• Bridge Over Temperature → Indicates that the bridge temperature has exceeded the upper limit.
• Motor Over Temperature → Indicates that the motor temperature has exceeded the upper limit.
• Short Circuit Bottom → Indicates a short circuit fault
• Velocity Rampdown → Indicates a timeout fault during a velocity rampdown (quickstop).
• Manual Mode → Indicates whether manual mode is enabled. This is a warning only.