B.2.16.48 Memory Status Byte 2
MEMORY STATUS BYTE 2 :
Power Save NVM Checksum Indicates that the checksum for the data in the drive internal power save
NVM is incorrect. This is for information only, it does not cause a fault condition on the drive.
Error log NVM Checksum Indicates that the checksum for the data in the drive internal error log NVM is
incorrect. This is for information only, it does not cause a fault condition on the drive.
B.2.16.49 Power Status Byte 1
POWER STATUS BYTE 1 :
Bus Over-Voltage Indicates that the bus over-voltage limit is exceeded.
Bus Under-Voltage Indicates that the bus under-voltage limit is exceeded.
Regen Initialisation Indicates a fault during regeneration initialisation.
Regen Short-Circuit Indicates that there is a regeneration short circuit fault.
Bus Voltage Indicates whether bus voltage is active.
Dynamic Brake Indicates that there is a dynamic brake fault.