APPENDIX B – GUI B-45
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.48 Memory Status Byte 2
MEMORY STATUS BYTE 2 :
• Power Save NVM Checksum → Indicates that the checksum for the data in the drive internal power save
NVM is incorrect. This is for information only, it does not cause a fault condition on the drive.
• Error log NVM Checksum → Indicates that the checksum for the data in the drive internal error log NVM is
incorrect. This is for information only, it does not cause a fault condition on the drive.
B.2.16.49 Power Status Byte 1
POWER STATUS BYTE 1 :
• Bus Over-Voltage → Indicates that the bus over-voltage limit is exceeded.
• Bus Under-Voltage → Indicates that the bus under-voltage limit is exceeded.
• Regen Initialisation → Indicates a fault during regeneration initialisation.
• Regen Short-Circuit → Indicates that there is a regeneration short circuit fault.
• Bus Voltage → Indicates whether bus voltage is active.
• Dynamic Brake → Indicates that there is a dynamic brake fault.