User`s manual
APPENDIX B – GUI  B-38 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
B.2.16.37  Moog Nonstandard Motors 
The ‘Create Entry’ button allows the user to create a new non-standard motor entry. It opens a panel providing 
tools for creation of the motor database parameters. 
Select a motor by double-clicking on the appropriate motor name. 
Alternatively, if a standard motor is similar to the motor required, then the standard motor parameters can be 
altered and saved as a Non-standard motor: 
Select the similar motor e.g. a G424-400, and make the changes required e.g. a Heidenhain encoder feedback is 
required instead of resolver feedback. 
Change the motor name to an easily recognisable name e.g. G424-400_Enc. 
Change the appropriate parameters: 
Commutation feedback 
source changed to 2 
(encoder feedback). 
Encoder type changed to 
5 (Heidenhain encoder) 
Ensure encoder supply 
voltage is correct (+5V 
in this case). 