User`s manual
APPENDIX B – GUI B-34
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.33 Resolver Parameters
The Resolver Parameters panel allows the user to set the parameters of this motor position feedback sensor.
• Resolver Poles → The number of resolver poles.
• Resolver Transformer Turns Ratio → A physical characteristic of the resolver, which determines the amplitude
of the resolver reference.
• Resolver reference amplitude → This is the voltage output from the DS2110 to drive the resolver.
• Resolver position → The multi-turn position derived from the resolver input position and used as feedback in
the position loop if resolver position is selected for the position loop feedback
• Resolver commutation position → The electrical angle of the resolver. Depending on the pole count of the
resolver this value is proportional to the mechanical angle.