User`s manual

APPENDIX B – GUI B-33
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.16.32 Motor Parameters
The Motor Parameters panel allows the user to set/read the electrical parameters of the motor.
A number of parameters are required when configuring a specific motor drive. For standard motors, these
parameters are implemented in the GUI’s database.
For non-standard motors, the user must enter these parameters. This can be done using this panel but it is
preferable to set up the non-standard motor in the non-standard motor database so that it is available for future
use.
MOTOR PARAMETERS
d-axis inductance (H) The inductance value of d-axis.
q-axis inductance (H) The inductance value of q-axis.
Terminal-Terminal resistance (Ohm) The terminal-to-terminal resistance of the motor.
Ke (V/rad/s) The Ke factor of the motor.
No. of Poles The number of motor poles. It can be set from 2 to 36.
Max. Continuous RMS Current (A) The maximum continuous RMS current of the motor.
Max. Motor Speed (deg/s) The maximum speed of the motor.
Resolver Poles The number of resolver poles.
Commutation offset →The value of the commutation offset.