B.2.16.24 Current Limits
The Current Limits panel allows the user to see and set the current limit parameters.
CURRENT LIMIT PARAMETERS :
Max. Current (combined) (A) This is the minimum of all of the maximum currents set for the application.
This is the current used as the maximum current demand for the current loop.
Nominal Sensed Current (A) This is the maximum current that can be sensed by the drive – this is set
automatically at power up for the power stage being used.
Controller Max. Current (A) This is the maximum current (peak) available from the drive – this is set
automatically at power up for the power stage being used.
Motor Max. Current (A) The maximum current that can be used with the attached motor – this is set
automatically at power up for the motor being used.
Max. Torque Limit (Nm) This can be used to limit the maximum current to a lower value than that obtained
from the minimum of the motor and drive maximum currents. If this is not necessary then this parameter
should be set to a very high value so that it has no effect.