The following table details the recommended cable dimensions for all DS2110 models
DS2110 Models Notes
µA A B
Cable 3/9
AWG
(mm
2
)
6/22
AWG
(mm
2
)
8/22
AWG
(mm
2
)
10/42
AWG (mm
2
)
14/42
AWG (mm
2
)
Line Power 3x14 (2.1) 3x12 (3.3)
Protective Bonding Cable 1x 6 (13)
Motor Power Cable 4x14 (2.1) 4x12 (3.31) Shielded
Regen Resistor Cable 2x14 (2.1) Shielded
DC Bus Cable 2x14 (2.1) Shielded
Safety Interlock (If
applicable)
2x22 (0.3) Shielded
24V Power Cable 2x14 (2.1) Shielded
Note: 2x14 (2.08) = Number of conductors x conductor size (AWG = American wire gauge)
DS2110 Models Notes
C D
Cable 20/45
AWG
(mm
2
)
25/70
AWG
(mm
2
)
30/90
AWG
(mm
2
)
50/140
AWG (mm
2
)
60/180
AWG (mm
2
)
Line Power 3x8 (8.4) 3x 6 (13) 3x 4 (21)
Protective Bonding Cable 1x 6 (13) 1x6 (13) 1x4 (21)
Motor Power Cable 4x8 (8.4) 4x6 (13) 4x4 (21) Shielded
Regen Resistor Cable 2x8 (8.4) 2x 6 (13) 2x4 (21) Shielded
DC Bus Cable 2x8 (8.4) 2x 6 (13) 2x4 (21) Shielded
Safety Interlock (If
applicable)
2x22 (0.3) Shielded
24V Power Cable 2x14 (2.1) Shielded
DS2110 Models Notes
E
Cable 100/240
AWG (mm
2
)
Line Power 3 x 1 (42)
Protective Bonding Cable 1 x 1 (42)
Motor Power Cable 4 x 1 (42) Shielded
Regen Resistor Cable 2 x 2 (34) Shielded
DC Bus Cable 2 x 1 (42) Shielded
Safety Interlock (If applicable) 2x22 (0.3) Shielded
24V Power Cable 2 x 14 (2.1) Shielded
Table 2 - DS2110 Cable Dimensions