User`s manual
APPENDIX B – GUI  B-17 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
For the bridge the parameters are: 
•  End Bridge temp. → read only value, calculated from start + span. At this temperature the current is reduced 
to 0. 
•  Max. Bridge temp.→ the temperature at which an over-temperature fault is indicated 
•  Start Bridge temp. → read only value, which takes the value of ‘Start Bridge temp. STALL’ if the motor speed 
is less than 50RPM and otherwise takes the value of Start Bridge temp. RUN 
•  Span Bridge temp. → read only value, which takes the value of ‘Span Bridge temp. STALL’ if the motor speed 
is less than 50RPM and otherwise takes the value of Span Bridge temp. RUN 
•  Bridge Thermal Limit Factor → the actual value of the thermal limit factor (a value between 0 and 1.0) 
•  Start Bridge temp. STALL → the temperature at which thermal limiting starts to act for motor speed of 
≤50RPM 
•  Span Bridge temp. STALL → the temperature range over which the current is reduced to 0 for motor speed of 
≤50RPM. 
•  Start Bridge temp. RUN → the temperature at which thermal limiting starts to act for motor speed of >50RPM 
•  Span Bridge temp. RUN → the temperature range over which the current is reduced to 0 for motor speed of 
>50RPM 
B.2.16.12  Manual Mode Limiting 
The Manual Mode Limiting panel allows the user to set the parameters of this mode. 
•  Current/Velocity Limit as % of Max. (%)→ it allows the user to set the current/velocity limit as a percent of the 
max value. 










