User`s manual
APPENDIX B – GUI B-17
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
For the bridge the parameters are:
• End Bridge temp. → read only value, calculated from start + span. At this temperature the current is reduced
to 0.
• Max. Bridge temp.→ the temperature at which an over-temperature fault is indicated
• Start Bridge temp. → read only value, which takes the value of ‘Start Bridge temp. STALL’ if the motor speed
is less than 50RPM and otherwise takes the value of Start Bridge temp. RUN
• Span Bridge temp. → read only value, which takes the value of ‘Span Bridge temp. STALL’ if the motor speed
is less than 50RPM and otherwise takes the value of Span Bridge temp. RUN
• Bridge Thermal Limit Factor → the actual value of the thermal limit factor (a value between 0 and 1.0)
• Start Bridge temp. STALL → the temperature at which thermal limiting starts to act for motor speed of
≤50RPM
• Span Bridge temp. STALL → the temperature range over which the current is reduced to 0 for motor speed of
≤50RPM.
• Start Bridge temp. RUN → the temperature at which thermal limiting starts to act for motor speed of >50RPM
• Span Bridge temp. RUN → the temperature range over which the current is reduced to 0 for motor speed of
>50RPM
B.2.16.12 Manual Mode Limiting
The Manual Mode Limiting panel allows the user to set the parameters of this mode.
• Current/Velocity Limit as % of Max. (%)→ it allows the user to set the current/velocity limit as a percent of the
max value.