User`s manual
APPENDIX B – GUI  B-12 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
B.2.16.5  Position Mode Preset 
The Position Mode Preset panel allows the user to set the mode request when a position control mode is 
requested. The default value for this parameter is 34776 (87D8 hex) indicating that bits 3, 4, 6, 7, 8, 9, 10 and 15 
are set. Note that bit 6 must always be set in this parameter; bits 0 and 1 must never be set in position mode. 
The user can set the following commands: 
• Acceleration Limiting → ON/OFF (bit 10) 
•  Command Micro Interpolation → ON/OFF (bit 9) 
•  d,q Gain Calibration → ON/OFF (bit 8) 
•  Time Optimal Position Loop → ON/OFF (bit 7) 
• Position Mode → ON/OFF (bit 6) 
• Field weakening → ON/OFF (bit 5) 
• Observer → ON/OFF (bit 4) 
• Generic Filter → ON/OFF (bit 3) 