User`s manual
APPENDIX B – GUI B-6
CDS7324 (FORMERLY LSF-0819)
Rev. A INSTALLATION & USER’S MANUAL
B.2.11 Event Logger
The Event Logger is one of the four large panels in the Main Window. It is located at the bottom left of the Main
Window, directly under the Navigator. The purpose of the Event Logger is to allow the user to record any
parameter read and / or parameters write events. Logging events can be useful in order to see what is being read
from or written to the controller at the lowest level. For each logged event the event type, parameter name,
parameter number, value, status, and timestamp are logged.
B.2.12 Event Logger Toolbar
The Event Logger toolbar consists of the following buttons.
Start Logging
If the Start Logging toggle button is depressed, the Event Logger logs those events whose filter toggle buttons
(i.e. Log Read Parameter or Log Write Parameter) also are depressed.
Stop Logging
If the Stop Logging toggle button is clicked, all logging is stopped. Clicking the Start Logging button can
recommence logging.
Clear Log
Clicking the Clear Log button completely clears the Event Logger.
Log Read Parameter
The Log Read Parameter toggle button needs to be depressed if any parameter read events are to be logged.
Log Write Parameter
The Log Write Parameter toggle button needs to be depressed if any parameters write events are to be logged.