APPENDIX A - DATA LOGGER  A-4 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
A.1.5 Example 
1.  set trigger mode to stop (trigger_mode = 0x03) 
2.  wait until trigger status is initialized (trigger_status: 0x00) 
3.  set number of samples to 1000 (data_logger_memory_size = 1000) 
4.  disable channels 1 to 3 (data_logger_enable[1-3] = 0x00) 
5.  enable channel 0 (data_logger_enable[0] = 0x01) 
6.  set channel 0 input to field number of position (data_logger_channel[0] = field number actual drive 
position) 
7.  set pre divider to 1 (data_logger_divider_factor = 1) 
8.  set trigger input to parameter number of position (trigger_field_number = field number actual drive 
position) 
9.  set trigger coupling to dc (trigger_coupling = 0x01) 
10. set trigger slope to rising (trigger_slope = 0x01) 
11. set trigger level to 0 (trigger_level_32-bit = 0) 
12. set trigger delay to 0 (trigger_delay = 0) 
13. set trigger mode to single (trigger_mode = 0x02). trigger status should go to waiting for trigger 
(trigger_status: 0x01) 
14. move position around zero position trigger status should go to sampling (trigger_status: 0x02) 
15. wait until trigger status is ready (trigger_status: 0x03) 
16. read DLGDIS (500) samples from data logger channel data (data_logger_channel_0) 