5.12 Drive Monitoring & Fault Detection 
5.12.1 Drive Monitoring 
The DS2110 monitors a range on internal and external drive voltages, temperatures, times and powers to ensure 
that the drive is operating correctly. Depending on the state of these feedback signals, the drive will react 
appropriately to ensure safe and reliable operation.  The parameters monitored are listed below. 
Temperatures 
Parameter Name  Field No.  Description 
bridge_temperature  1368  Power Amplifier Bridge Temperature 
motor_temperature  1373  Motor Winding Temperature 
ambient_temperature  1378  Control Electronics Ambient Temperature 
Table 5.37 Monitored Temperatures 
Voltages 
Parameter Name  Field No. / Subindex  Description 
supply_+24V  1441  Internal 24V Logic Supply 
supply_+3V3  1421  3.3V Logic Supply 
supply_-15V  1426  -15V Logic Supply 
supply_+15V  1431  +15V Logic Supply 
supply_+2.5V_ref.  1436  2.5V Reference Level 
encoder_ supply  1446 Encoder Supply 
bus_voltage_actual  1232  DC Bus Voltage 
Table 5.38 Monitored Voltages 
Times (Elapsed time Indicator) 
Parameter Name  Field No. / Subindex  Description 
ETI_total_power_on_time  1482  Total powered up time 
ETI_power_on_time_since_power_on  1483  Power up time since power up 
ETI_number_of_power_downs  1484  Number of power downs 
ETI_enabled_time  1485  Total enable time 
ETI_enabled_time_since_power_on  1486  Enabled time since power up 
ETI_enabled_time_since_enable  1487  Current enabled time 
Table 5.39 Monitored Times 
Power 
Parameter Name  Field No. / Subindex  Description 
regen_power_filtered  1252  Average Regeneration Power (Measured) 
Table 5.40 Monitored Powers 