CHAPTER 5.0 Functional Overview  5-24 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
5.8 Position Feedback 
The feedback signal for the position loop closure can be derived from the resolver input or the encoder input. 
5.8.1 Position Feedback Configuration 
5.8.1.1  Position feedback 
The selection of the position feedback is done through parameter position_feedback
 (Field Number 1168). It can 
have the following values: 
1  -  position feedback from resolver 
2  -  position feedback from encoder 
See 'Resolver Module' and 'Encoder Module' for further information on how to set up resolvers and encoders. 
5.8.2  Position feedback parameters 
position_feedback  
Data type  unsigned 8-bit 
Access  read / write 
Default value  1 
Minimum value  1 
Maximum value  2 
Storage type  customer settings eeprom 
Data group  application parameter 
Field number  1168 