User`s manual
CHAPTER 5.0 Functional Overview  5-3 
CDS7324 (FORMERLY LSF-0819)   
Rev. A  INSTALLATION & USER’S MANUAL 
5.3.2  High Voltage Rectification and Filtering 
The a.c. mains input is rectified by a three phase diode bridge and filtered by a bank of electrolytic capacitors to 
generate the internal DC Bus. This high power d.c. supply is unregulated and will vary in direct proportion with the 
a.c. mains input voltage magnitude. The dc bus voltage is monitored continuously and is available for user 
display, parameter bus_voltage_actual 
 (Field Number 1232). Once the softstart relay has closed, the nominal DC 
bus voltage is set in software, parameter bus_voltage_nominal
 (Field Number 1229), which will limit the maximum 
speed at which a motor can rotate. 
The software will generate a fault on both undervoltage (F12) and overvoltage (F2) level being detected. The 
undervoltage level, parameter bus_under_voltage_limit
 (Field Number 1234) is set, by default, to 75% of the 
nominal bus voltage. This undervoltage percentage level, parameter bus_under_voltage_limit_percentage
 (Field 
1235) can be changed to different levels to suit application requirements.. 
 The overvoltage level parameter bus_over_voltage_limit
 (Field Number 1233) is typically set by the motor 
configuration and will generally be either 400V or 800V. Bus voltage level is based on equation: A.C. Mains x 
1.414 = D.C. Bus. 
A.C. Mains Type  D.C. Bus Voltage Level 
230V Three Phase Mains  325Vd.c. 
480V Three Phase Mains  679Vd.c. 
Table 5.1 Magnitude of the D.C. Bus 
5.3.3 Soft Start 
Soft start is used to limit the inrush current to the d.c. bus capacitor bank on application of a.c. mains power. This 
is intended to prevent nuisance tripping of circuit breakers or blowing of line fuses on power-up. 
The soft start relay will close when the monitoring circuit and associated control software determines that the 
high-voltage d.c. bus has charged up and the DC bus is at steady state. Softstart will only occur if the DC bus 
voltage level is above 70V. 