4.7 Regen Resistor Configuration
µA size and select A and B size DS2110 are equipped with an internal regeneration resistor. All other A to E size
drives will require an external resistor to be attached. The recommended regeneration resistors are detailed in
Section 5.3.5.
The Regen-on/ Regen-off voltages should be set in accordance with the DC Bus voltage, Table 5.4 Typical
Regeneration Turn-on & Turn-off Voltage Levels. These parameters are automatically set when the motor
parameters are downloaded to the controller but should be verified to ensure safe operation.
Open “DS2110
→
Drive Setup
→
Regen Resistor
→
Regen Parameters” and ensure that the “Regen-On
Voltage (V)” and “Regen-Off Voltage (V)” are set correctly
Select Read All.
Confirm that values are correct.
Figure 4.5 Regeneration Parameters