User`s manual

SECTION 1: DS2100 OVERVIEW
DS2100 User's Manual
C27750-001 PAGE 1-7
1.3 Environmental Specifications
DS2100 Electronics
Temperature for storage: -25 °C to 55 °C (Class 1K4)
Temperature for transport: -25 °C to 70 °C (Class 2K3)
Maximum surrounding air temperature: 0 °C to 40 °C
Relative Humidity: 5 % to 85 %, non-condensing, 1 g/m
3
to 25 g/m
3
,
in accordance with EN50178 class 3k3
Elevation: 1000m (3,300 feet)
Derate output 2% per 300m (1000 feet) above 1000m (3300 feet)
Air Pressure: 86 kPa to 106 kPa
Type of protection: Components must be installed into an enclosure.
The enclosure must provide at least IP54 per standard
EN60529 or equivalent.
Pollution Degree: Drive is suitable for installation in a Pollution Degree 2
environment.
Installed position: Vertical only.
Overvoltage protection class: Category 2 per standard VDE0110 / IEC664
Noise: Overall noise depends on the user installation and cabinet.