User`s manual
SECTION 3: WIRING AND INSTALLATION
DS2100 User's Manual
C27750-001 PAGE 3-41
3.9.5 E Size DC Bus Inter-connection
Tie screen to chassis via
EMC bracket. See Section 2
L1 L2 L3 PE
(J9.6)(J9.7)(J9.8) (J9.5)
Connector J9
DC+ DC-
(J9.13) (J9.
14)
DS2100 E
L1 L2 L3 PE
(J9.6)(J9.7)(J9.8) (J9.5)
DC+ DC-
(J9.13) (J9.14)
DS2100 E
a.c. Mains
L1
L2
L3
Protective
Earth
Connector J9
Figure 3.29 Size D DC Bus Inter-connection
J9
- Fixed connector: 2 pole, screw terminal
- E size wiring: cable 1 AWG (42 mm
2
)
- PE Terminal wiring: cable 1 AWG (42 mm
2
)
- Stripping Length: 24mm
- Tightening Torque: 8Nm
Pos.
Name
Function
J9.13
DC+ DC Bus (+)
J9.14 DC- DC Bus (-)
Table 3-13 J9, DC Bus connector, E Size