User`s manual
SECTION 3: WIRING AND INSTALLATION
DS2100 User's Manual
C27750-001 PAGE 3-27
3.7 Three-Phase A.C. Mains Power Source Configuration
The DS2100 may be supplied from a three-phase a.c. mains input. In this case the following user supplied options are
required:-
1. Three-Phase Mains Fusing
2. Mains Line Filter
3. 24Vd.c. Power Source & Fuse
4. 24V d.c. EMC Filter
Note that for DS2100 sizes A,B,C, D & E, if the a.c. mains is still applied, and the control-backup power is removed,
then the DS2100 control section will still operate correctly. Control power can still be generated from the high voltage
D.C. Bus.
below outlines typical interconnect in a multi-axis DS2100 system, which is powered by 3-phase a.c. mains supply.