User`s manual

DS2100 User's Manual APPENDIX B: GUI
PAGE 68
B.3.16.52 Digital Output Configuration
The Digital Output Configuration panel allows the user to set digital output parameters.
There are 3 digital outputs on the DS2100. All 3 outputs are user-configurable.
DIGITAL OUTPUT CONFIGURATION :
DIGITAL OUTPUT (1, 2, 3)
Parameter Number The specific parameter that is to be associated with the digital output. The
field value of the parameter must be entered into the digital output field number parameter, to
specify the parameter of interest.
o Digital Output 1 defaults to drvsts
o Digital Output 2 defaults to limact
o Digital Output 3 defaults to diginp
Bit Mask Specify bits used to determine state of digital output within the parameter. This
mask is ANDED with the parameter specified by the field number to determinate the digital
output state.
Invert Invert the logic of the digital output.