User`s manual

DS2100 User's Manual APPENDIX B: GUI
PAGE 46
For the bridge the parameters are:
End Bridge temp. read only value, calculated from start + span. At this temperature the
current is reduced to 0.
Max. Bridge temp. the temperature at which an over-temperature fault is indicated
Start Bridge temp. read only value, which takes the value of ‘Start Bridge temp. STALL’ if
the motor speed is less than 50RPM and otherwise takes the value of Start Bridge temp. RUN
Span Bridge temp. read only value, which takes the value of ‘Span Bridge temp. STALL’ if
the motor speed is less than 50RPM and otherwise takes the value of Span Bridge temp. RUN
Bridge Thermal Limit Factor the actual value of the thermal limit factor (a value between 0
and 1.0)
Start Bridge temp. STALL the temperature at which thermal limiting starts to act for motor
speed of 50RPM
Span Bridge temp. STALL the temperature range over which the current is reduced to 0 for
motor speed of 50RPM.
Start Bridge temp. RUN the temperature at which thermal limiting starts to act for motor
speed of >50RPM
Span Bridge temp. RUN the temperature range over which the current is reduced to 0 for
motor speed of >50RPM