DS2100 User's Manual APPENDIX B: GUI
PAGE 46
For the bridge the parameters are:
• End Bridge temp. → read only value, calculated from start + span. At this temperature the
current is reduced to 0.
• Max. Bridge temp.→ the temperature at which an over-temperature fault is indicated
• Start Bridge temp. → read only value, which takes the value of ‘Start Bridge temp. STALL’ if
the motor speed is less than 50RPM and otherwise takes the value of Start Bridge temp. RUN
• Span Bridge temp. → read only value, which takes the value of ‘Span Bridge temp. STALL’ if
the motor speed is less than 50RPM and otherwise takes the value of Span Bridge temp. RUN
• Bridge Thermal Limit Factor → the actual value of the thermal limit factor (a value between 0
and 1.0)
• Start Bridge temp. STALL → the temperature at which thermal limiting starts to act for motor
speed of ≤50RPM
• Span Bridge temp. STALL → the temperature range over which the current is reduced to 0 for
motor speed of ≤50RPM.
• Start Bridge temp. RUN→ the temperature at which thermal limiting starts to act for motor
speed of >50RPM
• Span Bridge temp. RUN → the temperature range over which the current is reduced to 0 for
motor speed of >50RPM