User`s manual
APPENDIX B: GUI DS2100 User's Manual
C27750-001 PAGE 33
FEEDBACK PARAMETERS → Allows the user to see the value of the three feedback parameters. The
parameters are:
• Position Demand Value → Output from Demand Block in position units.
• Position Demand Value* → Output from Demand Block in units of increments.
• Position Actual Value → Actual value from the position measurement device, in position units.
• Position Actual Value* → Actual value from the position measurement device, in incs.
CONTROL WORD BITS → Allows the user to set the control word bits.
• New Set – Point → Set the next target position.
• Change Set Immediately → Interrupt the actual positioning and then start the next positioning.
• Absolute/Relative (PPM Only) → Select whether target value is absolute or relative.
STATUS WORD BITS → Allows the user to see the state of word bits.
• Target Reached → Indicates that the target position has been reached.
• Set Point Acknowledge → Indicates if the Drive has assumed the positioning values.