User`s manual

APPENDIX B: GUI DS2100 User's Manual
C27750-001 PAGE B-21
B.3.16.11 DS402 Factor Group Input
The DS402 Factor Group Input Parameters panel allows the user to set factor group input parameters for
scaling between physical units used by the user, and internal units of the drive.
Position Notation Index This parameter allows the user to select the position notation index
(the power of 10 for the position units).
Position Dimension Index This parameter allows the user to select the position dimension unit
type between meters ,radians ,seconds, minutes, degrees and revs.
Velocity Notation Index This parameter allows the user to select the velocity notation index
(the power of 10 for the velocity units).
Velocity Dimension Index This parameter allows the user to select the velocity dimension
unit type between m/sec, m/min, m/hour, rev/sec, rev/min and rev/hour.
Acceleration Notation Index This parameter allows the user to select the acceleration notation
index (the power of 10 for the acceleration units).
Acceleration Dimension Index This parameter allows the user to select the acceleration unit
type between m/sec^2, m/min^2, rev/sec^2 and rev/min^2.
Position Polarity This parameter allows the user to invert the position polarity.
Velocity Polarity This parameter allows the user to invert the velocity polarity.
Position Encoder Resolution - incs Used in conjunction with the ‘position encoder resolution –
revs’ parameter to set the position encoder resolution.
Position Encoder Resolution – revs Used in conjunction with the ‘position encoder resolution
– incs’ parameter to set the position encoder resolution. Resolution = incs/rev
Vel. Encoder Resolution – incs/sec Used in conjunction with the ‘position encoder resolution
– revs/sec’ parameter to set the position encoder resolution.
Vel. Encoder Resolution – revs/sec Used in conjunction with the ‘position encoder resolution
– incs/sec’ parameter to set the position encoder resolution. Resolution = (incs/sec)/(revs/sec)
Gear Ratio – motor revs Used in conjunction with the ‘Gear Ratio – shaft revs to set the gear
ratio.
Gear Ratio – shaft revs Used in conjunction with the ‘Gear Ratio – motor revs’ parameter to
set the gear ratio. Gear Ratio = motor revs/shaft revs.
Feed Constant - feed Used in conjunction with the ‘Feed Constant – shaft revs to set the feed
constant.
Feed Constant – shaft revs Used in conjunction with the ‘Feed Constant - feed’ parameter to
set the feed constant. Feed Constant = feed/shaft revs.