Shielded cable is required to be installed by the user for many external user cable connections to the DS2100. Details of
areas where shielded cable must be installed and details of earthing arrangements which must be implemented for the
shields of such cables are given throughout Section 3 of this User’s Guide.
2.3.2 Recommended EMC Filters
No internal filtering is provided in the DS2100. To ensure EMC compliance an external line filter must be installed. The
recommended filters for the DS2100 are detailed below.
DS2100 µ
µµ
µA Size
Moog Order
Code
Manufacturer Rated Current (A)
@ 50
o
C (40
o
C)
Max Voltage
Drive Input
- Schaffner Fairite Clamp. Part
# 00443164151
- - 24V
dc
Input
(4 Turns in Common Mode)
AT6009 Schaffner FN 258-7/07 7 (8.4) 3x480V 3-phase AC Line Input
- Schaffner FN 350-12/29 12 (13.8) 1x250V 1-phase AC Line Input
(µA 3/11 only)
DS2100 A,B,C,D, E Sizes
Moog Order
Code
Manufacturer Rated Current (A)
@ 50
o
C (40
o
C)
Max Voltage
Drive Input\Size
AT6017
1
Schaffner FN2070-3-06 (3) 250V 24V
dc
Input
AT6009 Schaffner FN258-7/07 7 (8.4) 3x480V 3-phase AC Line Input
(Size A)
AT6010 Schaffner FN258-16/07 16 (19.2) 3x480V 3-phase AC Line Input
(Size B)
AT6011 Schaffner FN258-30/07 30 (36) 3x480V 3-phase AC Line Input
(Size C)
AT6012 Schaffner FN258-42/07 42 (50.4) 3x480V 3-phase AC Line Input
(Size D 50/140)
AT6013 Schaffner FN258-55/07 55 (66) 3x480V 3-phase AC Line Input
(Size D 60/180)
AT6015 Schaffner FN258-100/35 100 (113) 3x480V 3-phase AC Line Input
(Size D 100/300)
Table 2.3 Recommended EMC Filters for DS2100
1
The 24Vdc filter can be used with two DS2100 drives. If more than two DS2100 drives are in use on a machine, a filter
from the same series can be used with a higher current rating.
This equipment intended to be connected to an industrial low-voltage power supply network, or
public network, which does not supply buildings used for domestic purposes (second
environment, according to EMC Standards). If connected to a low-voltage public network that
supplies domestic premises (first environment), this product is expected to cause radio
interference in which case supplementary measures may be required.